Instalación de IBM z/OS V1R4

El z/OS V1R4 se encuentra disponible en forma de AD-CD (Application Development CD). Este sistema son 16 volúmenes de discos 3390-3 a los que se les ha hecho un dump físico, por lo que dispone de residentes, DLIBs, customizaciones y diversos productos (TSO, CICS, DB2, etc). Además, también se incluye un fichero de configuración que el hercules interpreta como si fueran unas fichas IOCDS, lo que hace que el Hercules asigne IODEVICEs predefinidos por la instalación.

#
# Configuration file for Hercules & IBM ADCD z/OS 1.4
#
CPUSERIAL 000000 # CPU serial number
CPUMODEL 9672 # CPU model number
MAINSIZE 768 # Main storage size in megabytes
XPNDSIZE 0 # Expanded storage size in megabytes
CNSLPORT 23 # TCP port number to which consoles connect
NUMCPU 1 # Number of CPUs
TZOFFSET +0100
OSTAILOR OS/390 # OS tailoring
PANRATE FAST # Panel refresh rate
ARCHMODE ESAME # Architecture mode S/370, ESA/390 or ESAME
PGMPRDOS LICENSED # Allow OS/390 and Z/OS systems to run
#
# IPL parameter
#
LOADPARM 0A82DC..
#
# 0A82xx.. xx : one of the following :
#
# CS CLPA and cold start of JES2. Base z/OS system functions i.e. no CICS, DB2, IMS, WAS, etc.
# 00 Warm start of JES2. Base z/OS system functions i.e. no CICS, DB2, IMS, WAS, etc.
# WS Warm start of JES2. Base z/OS system functions i.e. no CICS, DB2, IMS, WAS, etc.
# DC CLPA, brings in CICS LPA modules, cold start of JES2, starts up DB2 and CICS.
# DB Warmstart of JES2 and starts the DB2 and CICS.
# DI CLPA and cold start of JES2 and loads the IMS Libraries. IMS must be manually started.
# CC CLPA and cold start of JES2, loads the CICS Libraries, starts up CICS, no DB2.
# CW Warm start of JES2, and starts up CICS.
# 2C CLPA, cold start of JES2, starts up DB2, no CICS.
# 2W Warm start of JES2, starts up DB2, no CICS.
# IC CLPA and cold start of JES2 and load the IMS Libraries, start IMS, no DB2 or CICS.
# IW Warm start of JES2 start IMS, no DB2 or CICS.
# AC CLPA and cold start of JES2 load IMS and CICS libraries, start IMS, DB/2, and CICS.
# AW Warmstart of JES2. start IMS, DB/2, and CICS.
# BC CLPA and cold start of JES2, load WAS libraries, WAS is manually started
# AW Warmstart of JES2. start IMS, DB/2, and CICS.
# BC CLPA and cold start of JES2, load WAS libraries, WAS is manually started
# BW Warmstart of JES2. WAS is manually started.
# 99 Points to IODF99 for IPL on MP3000.
# Reply 00,SYSP=xx were xx is any of the above options i.e. for cics only xx=cc or cw.
# Device list
#--- ---- --------------------

0500 3490 *
0560 3480 *
0700 3270
0701 3270
0702 3270
0900 3270
0901 3270
0A80 3390 /ZOS14/s4res1.a80
0A81 3390 /ZOS14/s4res2.a81
0A82 3390 /ZOS14/os39m1.a82
0A83 3390 /ZOS14/s4db21.a83
0A84 3390 /ZOS14/s4cic1.a84
0A85 3390 /ZOS14/s4dis1.a85
0A86 3390 /ZOS14/s4dis2.a86
0A87 3390 /ZOS14/s4uss1.a87
0A88 3390 /ZOS14/s4dis3.a88
0A89 3390 /ZOS14/s4ims1.a89
0A8A 3390 /ZOS14/s4was1.a8a
0A8B 3390 /ZOS14/s4was2.a8b
0A8C 3390 /ZOS14/sares1.a8c
0A8D 3390 /ZOS14/s4dis4.a8d
0A8F 3390 /ZOS14/saipl1.a8f
0E20 3088 CTCI 10.10.10.1 10.10.10.2

About the Author